  • Dimension

The selected combination does not exist.

Variants

Item no.
Loading variants ...

ECTFE is a partly fluorinated fluoropolymer that is much stiffer and harder than PFA and FEP. It stands up to chemically aggressive media and handles alkaline environments above pH 10, where many other plastics give way. This roll has aramid fabric on the back, the code AB, which gives the adhesive its grip, since fluoropolymers cannot be glued.

The stiffness shows in the figures: the tensile modulus is 1 650 MPa against 450 for PFA, and the yield strength sits at 31 MPa. The material is tough, the notched impact strength is above 100 kJ/m². The dielectric strength is 23 kV/mm and the Vicat softening point 118 degrees. The temperature range is -40 to +150 degrees, so ECTFE does not take as much cold or heat as the fully fluorinated plastics.

The roll is supplied in natural and is used mainly for lining steel tanks and in composite construction against glass fiber reinforced plastic, where its low permeation is the whole point. The aramid side is laid against the load-bearing substrate. We cut the roll to the length and width you need.

Do you need technical documentation? Call us directly.

Technical specifications

Format
Rulle
Material
ECTFE AB
Length
20000 mm
Width
1500 mm
Thickness
1,5 mm
Machining
CNC Machining

Datorstödd bearbetning

Drilling

Håltagning med borr

Milling

Bearbetning med fräs

Sawing

Kapning med såg (band-, cirkelsåg)

Turning

Bearbetning i svarv

Property Value Unit Test standard
Density & Weight
Density 1,68 g/cm³ ISO 1183
Tensile Properties
Yield Stress 31 MPa DIN EN ISO 527
Tensile Modulus of Elasticity 1650 MPa DIN EN ISO 527
Strain at Yield 4 % ISO 527-2
Tensile Strain at Break >50 % DIN EN ISO 527
Impact Resistance
Charpy Notched Impact Strength > 100 kJ/m² ISO 179
Charpy Unnotched Impact Strength brister inte kJ/m² ISO 179
Hardness
Shore D Hardness 74 Shore D Shore D
Ball Indentation Hardness 56 MPa ISO 2039-1
Temperature Limits
Melting Point 240 till 245 °C ISO 3146
Max. Continuous Service Temperature -40 till +150 °C
Vicat Softening Temperature (VST/B/50) 118 °C ISO 306
Thermal Conductivity
Thermal Conductivity 0,15 W/(m·K) DIN 52612-1
Thermal Expansion
Coefficient of Linear Thermal Expansion 1,0 x 10⁻⁴ ISO 11359-2
Insulation Properties
Dielectric Strength 23 kV/mm IEC 60243-1
Static Dissipation
Surface Resistivity > 10¹³ Ω IEC 60093
Flammability Rating
Fire Classification Building (DIN 4102/EN 13501) B1 enligt DIN 4102